CCS Pattern Stamped Concrete

Strength

Results of tests conducted on crushing test cubes made from CCS Colour Hardener reveal the following typical strengths:

1 Day - 28 MPA
3 Days - 45 MPA
28 Days - up to 79 MPA

The above early, as well as long term strengths ensure a strong, abrasive-resistant finish is achieved.

Abrasion Resistance

Abrasion resistance actually improves with sufficient application of CCS Colour Hardener (coloured pre-mix) to the surface.

The following table details the potential increases in abrasion resistance gained from applying the recommended quantities of CCS Colour Hardener.

Surface Minimum 28 day abrasion index standard as per MA20 Average abrasion index of surface finished with CCS hardener* Result
Driveways and car parks with vehicular traffic under 3 tonnes 1.2 2.98 Exceeds Standard
Footpaths 1.2 2.98 Exceeds Standard
Public roads and industrial hardstands 1.5 2.98 Exceeds Standard
Busy shopping footpaths and malls with heavy pedestrian traffic 2.0 2.98 Exceeds Standard

*Results of tests by Queensland University of Technology conducted in accordance with Appendix D - MA 20 Abrasion Test, Specification for Concrete Segmented Paving Units. Surfaces were finished with CCS Colour Hardener at the rate of 2kg per m2.